OFFICIAL XPF MAP PREVIEW
SolarEdge SE5K / SE7K / SE10K / SE12.5K Modbus Register Map
SolarEdge SE5K / SE7K / SE10K / SE12.5K Modbus map and register map with sample Modbus registers, register addresses, and solar inverter overview for engineers. Works with Modbus Monitor XPF (import directly) and includes downloadable CSV access in-app.
Register preview
This public preview shows 12 representative read-oriented signals. The complete official map is available in Modbus Monitor XPF.
| Signal | Address | Type | Unit | Category |
|---|---|---|---|---|
| I AC VoltageAB | 440077 | UINT16 | V | Voltage |
| I AC Current | 440072 | UINT16 | - | Current |
| I AC Power | 440084 | INT16 | kW | Power |
| I AC Energy WH | 440094 | UINT32 | kWh | Energy |
| I AC Frequency | 440086 | UINT16 | Hz | Frequency |
| I AC PF1 | 440092 | INT16 | - | Power Factor |
| I Status | 440108 | UINT16 | - | Status |
| I Temp Sink | 440104 | INT16 | - | Temperature |
| C SunSpec ID | 440001 | UINT32 | - | General |
| C Model:16 | 440021 | STRING | - | Identification |
| M Exported | 440227 | UINT32 | - | Communication |
| I AC CurrentA | 440073 | UINT16 | - | Current |
Addressing note
Display address copied from the official XPF map preview. Modbus reference-number and zero-based offset conventions vary by device; verify the manufacturer manual before polling or writing.
Need the complete map?
Open the pre-built SolarEdge SE5K / SE7K / SE10K / SE12.5K map in Modbus Monitor XPF for the full register set, live polling, logging, and dashboards.
Open full map in XPF