  "$schema": "https://modbus-monitor.github.io/modbus-device-maps/schemas/modbus-map.schema.json",
  "schema_version": "1.1.0",
  "id": "selec/em2m-1p",
  "manufacturer": "Selec",
  "manufacturer_slug": "selec",
  "model": "EM2M-1P",
  "slug": "em2m-1p",
  "title": "Selec EM2M-1P Modbus Register Map",
  "description": "Official Modbus Monitor XPF preview for the Selec EM2M-1P power meter, with 12 representative energy, power, voltage signals.",
  "device_type": "Power Meter",
  "protocol": "Modbus RTU / Modbus TCP",
  "categories": [
    "Energy",
    "Power",
    "Voltage",
    "Current",
    "Frequency"
  ],
  "address_display_convention": "Display address copied from the official XPF map preview. Modbus reference-number and zero-based offset conventions vary by device; verify the manufacturer manual before polling or writing.",
  "registers": [
    {
      "name": "Voltage L-N",
      "display_address": "300020",
      "data_type": "FLOAT32",
      "unit": "V",
      "category": "Voltage"
    },
    {
      "name": "Current",
      "display_address": "300022",
      "data_type": "FLOAT32",
      "unit": "-",
      "category": "Current"
    },
    {
      "name": "Active power",
      "display_address": "300014",
      "data_type": "FLOAT32",
      "unit": "kW",
      "category": "Power"
    },
    {
      "name": "Total active energy",
      "display_address": "300000",
      "data_type": "FLOAT32",
      "unit": "kWh",
      "category": "Energy"
    },
    {
      "name": "Frequency",
      "display_address": "300026",
      "data_type": "FLOAT32",
      "unit": "Hz",
      "category": "Frequency"
    },
    {
      "name": "Import active energy",
      "display_address": "300002",
      "data_type": "FLOAT32",
      "unit": "kWh",
      "category": "Energy"
    },
    {
      "name": "Export active energy",
      "display_address": "300004",
      "data_type": "FLOAT32",
      "unit": "kWh",
      "category": "Energy"
    },
    {
      "name": "Total reactive energy",
      "display_address": "300006",
      "data_type": "FLOAT32",
      "unit": "kWh",
      "category": "Energy"
    },
    {
      "name": "Import reactive energy",
      "display_address": "300008",
      "data_type": "FLOAT32",
      "unit": "kWh",
      "category": "Energy"
    },
    {
      "name": "Export reactive energy",
      "display_address": "300010",
      "data_type": "FLOAT32",
      "unit": "kWh",
      "category": "Energy"
    },
    {
      "name": "Apparent energy",
      "display_address": "300012",
      "data_type": "FLOAT32",
      "unit": "kWh",
      "category": "Energy"
    },
    {
      "name": "Reactive power",
      "display_address": "300016",
      "data_type": "FLOAT32",
      "unit": "kW",
      "category": "Power"
    }
  ],
  "register_count": 12,
  "guide_status": "upcoming",
  "documentation_url": null,
  "product": {
    "name": "Modbus Monitor XPF",
    "full_map_url": "https://www.modbusmonitor.com/download?utm_source=github&utm_medium=referral&utm_campaign=device_maps&utm_content=selec/em2m-1p",
    "tester_url": "https://www.modbusmonitor.com/modbus-tester?utm_source=github&utm_medium=referral&utm_campaign=device_maps&utm_content=selec/em2m-1p",
    "request_url": "https://github.com/Modbus-Monitor/modbus-device-maps/issues/new/choose"
  },
  "license_notice": "See DATA_LICENSE.md and DISCLAIMER.md in the repository root."
}