  "$schema": "https://modbus-monitor.github.io/modbus-device-maps/schemas/modbus-map.schema.json",
  "schema_version": "1.1.0",
  "id": "schneider-electric/pm5000-pm5100-pm5300",
  "manufacturer": "Schneider Electric",
  "manufacturer_slug": "schneider-electric",
  "model": "PM5000 / PM5100 / PM5300",
  "slug": "pm5000-pm5100-pm5300",
  "title": "Schneider Electric PM5000 / PM5100 / PM5300 Modbus Register Map",
  "description": "Schneider Electric PM5000 / PM5100 / PM5300 Modbus map and register map with sample Modbus registers, register addresses, and power meter overview for engineers. Works with Modbus Monitor XPF (import directly) and includes downloadable CSV access in-app.",
  "device_type": "Power Meter",
  "protocol": "Modbus",
  "categories": [
    "Voltage",
    "Current",
    "Power",
    "Energy",
    "Demand",
    "Frequency"
  ],
  "address_display_convention": "Display address copied from the published preview. Modbus reference-number and zero-based offset conventions vary by device; verify the linked documentation and manufacturer manual before polling.",
  "registers": [
    {
      "name": "Nominal voltage V",
      "display_address": "402017",
      "data_type": "FLOAT32",
      "unit": "V",
      "category": "Voltage"
    },
    {
      "name": "Nominal current A",
      "display_address": "402019",
      "data_type": "FLOAT32",
      "unit": "-",
      "category": "Current"
    },
    {
      "name": "Number of control power failures",
      "display_address": "401828",
      "data_type": "UINT16",
      "unit": "kW",
      "category": "Power"
    },
    {
      "name": "Conditional energy control status",
      "display_address": "401999",
      "data_type": "UINT16",
      "unit": "kWh",
      "category": "Energy"
    },
    {
      "name": "Nominal frequency Hz",
      "display_address": "402016",
      "data_type": "UINT16",
      "unit": "Hz",
      "category": "Frequency"
    },
    {
      "name": "Demand system assignment",
      "display_address": "403760",
      "data_type": "UINT16",
      "unit": "kW",
      "category": "Demand"
    },
    {
      "name": "Revenue security status",
      "display_address": "401920",
      "data_type": "UINT16",
      "unit": "-",
      "category": "Status"
    },
    {
      "name": "Meter name",
      "display_address": "400029",
      "data_type": "STRING",
      "unit": "-",
      "category": "Identification"
    },
    {
      "name": "Manufacturer",
      "display_address": "400069",
      "data_type": "STRING",
      "unit": "-",
      "category": "General"
    },
    {
      "name": "Duration of last control power failure seconds",
      "display_address": "401833",
      "data_type": "UINT32",
      "unit": "kW",
      "category": "Power"
    },
    {
      "name": "Nominal power factor",
      "display_address": "402021",
      "data_type": "UINT32",
      "unit": "PF",
      "category": "Power"
    },
    {
      "name": "Peak current demand over last year A",
      "display_address": "402047",
      "data_type": "FLOAT32",
      "unit": "kW",
      "category": "Current"
    }
  ],
  "register_count": 12,
  "documentation_url": "https://docs.quantumbitsolutions.com/products/xpf/device-maps/schneider-electric/pm5000-pm5100-pm5300/",
  "product": {
    "name": "Modbus Monitor XPF",
    "full_map_url": "https://www.modbusmonitor.com/download?utm_source=github&utm_medium=referral&utm_campaign=device_maps&utm_content=schneider-electric/pm5000-pm5100-pm5300",
    "tester_url": "https://www.modbusmonitor.com/modbus-tester?utm_source=github&utm_medium=referral&utm_campaign=device_maps&utm_content=schneider-electric/pm5000-pm5100-pm5300",
    "request_url": "https://github.com/Modbus-Monitor/modbus-device-maps/issues/new/choose"
  },
  "license_notice": "See DATA_LICENSE.md and DISCLAIMER.md in the repository root.",
  "guide_status": "published"
}