  "$schema": "https://modbus-monitor.github.io/modbus-device-maps/schemas/modbus-map.schema.json",
  "schema_version": "1.1.0",
  "id": "kraft/flexkraft-dual",
  "manufacturer": "Kraft",
  "manufacturer_slug": "kraft",
  "model": "FlexKraft Dual",
  "slug": "flexkraft-dual",
  "title": "Kraft FlexKraft Dual Modbus Register Map",
  "description": "Official Modbus Monitor XPF preview for the Kraft FlexKraft Dual power meter, with 12 representative voltage, current, status signals.",
  "device_type": "Power Meter",
  "protocol": "Modbus RTU / Modbus TCP",
  "categories": [
    "Voltage",
    "Current",
    "Status"
  ],
  "address_display_convention": "Display address copied from the official XPF map preview. Modbus reference-number and zero-based offset conventions vary by device; verify the manufacturer manual before polling or writing.",
  "registers": [
    {
      "name": "Output voltage V",
      "display_address": "300004",
      "data_type": "INT16",
      "unit": "V",
      "category": "Voltage"
    },
    {
      "name": "Output current A",
      "display_address": "300005",
      "data_type": "INT16",
      "unit": "-",
      "category": "Current"
    },
    {
      "name": "Status register",
      "display_address": "300001",
      "data_type": "UINT16",
      "unit": "-",
      "category": "Status"
    },
    {
      "name": "Warnings register",
      "display_address": "300002",
      "data_type": "UINT16",
      "unit": "-",
      "category": "General"
    },
    {
      "name": "Alarms register",
      "display_address": "300003",
      "data_type": "UINT16",
      "unit": "-",
      "category": "Status"
    },
    {
      "name": "Output voltage A V",
      "display_address": "300004",
      "data_type": "INT16",
      "unit": "V",
      "category": "Voltage"
    },
    {
      "name": "Output current A A",
      "display_address": "300005",
      "data_type": "INT16",
      "unit": "-",
      "category": "Current"
    },
    {
      "name": "Output voltage B V",
      "display_address": "300006",
      "data_type": "INT16",
      "unit": "V",
      "category": "Voltage"
    },
    {
      "name": "Output current B A",
      "display_address": "300007",
      "data_type": "INT16",
      "unit": "-",
      "category": "Current"
    },
    {
      "name": "Process time s",
      "display_address": "300006",
      "data_type": "UINT32",
      "unit": "-",
      "category": "General"
    },
    {
      "name": "Ah Ah",
      "display_address": "300008",
      "data_type": "UINT32",
      "unit": "-",
      "category": "General"
    },
    {
      "name": "Process time s",
      "display_address": "300008",
      "data_type": "UINT32",
      "unit": "-",
      "category": "General"
    }
  ],
  "register_count": 12,
  "guide_status": "upcoming",
  "documentation_url": null,
  "product": {
    "name": "Modbus Monitor XPF",
    "full_map_url": "https://www.modbusmonitor.com/download?utm_source=github&utm_medium=referral&utm_campaign=device_maps&utm_content=kraft/flexkraft-dual",
    "tester_url": "https://www.modbusmonitor.com/modbus-tester?utm_source=github&utm_medium=referral&utm_campaign=device_maps&utm_content=kraft/flexkraft-dual",
    "request_url": "https://github.com/Modbus-Monitor/modbus-device-maps/issues/new/choose"
  },
  "license_notice": "See DATA_LICENSE.md and DISCLAIMER.md in the repository root."
}